Karolinska Institutet
Browse

Transoesophageal and transthoracic recordings of mitral annulus motion

Download (1.81 MB)
thesis
posted on 2024-09-02, 22:47 authored by Bo Nilsson

Maximal systolic and diastolic velocities recorded from four sites of the mitral annulus motion (MAM) reflect left ventricular (LV) performance. This thesis focus on factors influencing M-mode derived velocities in healthy children and adults and reference values are proposed. The usefulness of M-mode and pulsed tissue Doppler in detecting diastolic disturbances in patients with symptoms of heart failure are investigated as well. Also the reproducibility of transoesofageal (TE) recordings of long-axis movements and the difference to transthoracic (TT) recordings in anaesthetized patients are described as is the influence of respiration.

By applying tangents to M-mode echocardiography recordings from apical 2- and 4-chamber views the maximal systolic long axis velocity (MLACV) and maximal diastolic relaxation velocities (RVm) were measured. Based on stepwise multiple regression analysis concerning age, weight, height, body surface area and heart rate the following equations are suggested for calculation of reference values:

In children and adolescents under 18: MLACV (mm⁻¹) = 2.5 x Age (years) + 49.0, (±20.2) (±2 SEE); RVm (mm⁻¹) = 171 - 0.54 x Heart rate, (±37.4) (±2 SEE).

In adults: MLACV (mm⁻¹) = 0.75 x Height (cm) -50.5, (±19.6) (±2 SEE); RVm (mm⁻¹) = 163 - 1.29 x Age, (±16.8) (±2 SEE).

Intra- and inter-individual reproducibility expressed as the coefficient of variation for MLACV was 4.7% and 4.9% respectively.

In 64 patients with symptoms of heart failure the LV inflow and lung vein flow profiles were obtained by pulsed Doppler recordings and patients were classified as true cases of abnormal diastolic function by age corrected reference values. M-mode (M-RVm) and pulsed Doppler tissue imaging (TD-RVm) were used for recordings of RVm and according to Fisher's exact test both methods can be used to detect diastolic dysfunction but velocities obtained by TD-RVm was 29.7% (p<0.0001) higher than M-RVm. Sensitivity and specificity for M-RVm to correctly detect diastolic dysfunction were 89% and 81% respectively and for TD-RVm 81% and 78%. TD-RVm and M-RVm were highly correlated (r = 0.87).

Differences in TT and TE recordings of MAM were investigated in 24 healthy anaesthetized patients by using tissue velocity imaging. Another 10 patients were enrolled for the reproducibility study. The anterior site has low reproducibility and should be omitted when comparing TE and TT values. A TE mean value from three sites is about 15% lower than a TT mean value from four sites. Only systolic and early diastolic velocities have acceptable reproducibility values. Respiration does not influence MLACV or RVm during anaesthesia but RVm is about 5% higher during expiration in awake individuals.

List of scientific papers

I. Nilsson B, Bojo L, Wandt B (2000). Influence of body size and age on maximal systolic velocity of mitral annulus motion. Clin Physiol. 20(4): 272-8.
https://pubmed.ncbi.nlm.nih.gov/10886259

II. Nilsson B, Bojo L, Wandt B (2002). Influence of body size and age on maximal diastolic velocity of mitral annulus motion. J Am Soc Echocardiogr. 15(1): 29-35.
https://doi.org/10.1067/mje.2002.115617

III. Fornander Y, Nilsson B, Egerlid R, Wandt B (2004). Left ventricular longitudinal relaxation velocity: a sensitive index of diastolic function. Scand Cardiovasc J. 38(1): 33-8.
https://doi.org/10.1080/14017430310016018

IV. Nilsson B, Henningsson R, Brodin LA, Wandt B (2006). Transesophageal echocardiographic acquisition of mitral annulus motion during monotoring of left ventricular function in anesthetizec patients. J Am Soc Echocardiogram. 19. [Accepted]
https://doi.org/10.1016/j.echo.2005.12.002

History

Defence date

2006-02-24

Department

  • Department of Laboratory Medicine

Publisher/Institution

Karolinska Institutet

Publication year

2006

Thesis type

  • Doctoral thesis

ISBN-10

91-7140-640-9

Number of supporting papers

4

Language

  • eng

Original publication date

2006-02-03

Author name in thesis

Nilsson, Bo

Original department name

Department of Laboratory Medicine

Place of publication

Stockholm

Usage metrics

    Theses

    Categories

    No categories selected

    Keywords

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC