Optimization of intravenous contrast media at computed tomography

thesis
posted on 2024-09-03, 00:41 authored by Anders SvenssonAnders Svensson

The administration of intravenous contrast media (IV CM) is essential for detecting lesions at most computed tomography (CT) examinations. The overall aim of this thesis is to investigate different aspects of IV CM administration that may affect the quality of the CT examination.

In Study I a comparison was made between a low osmolar contrast media (LOCM) iomperol and the iso osmolar contrast media (IOCM) iodixanol, focusing on how they may affect heart rate, heart rate variability, experienced patient heat sensation and image quality at coronary computed angiography (CCTA) in 100 patients. No significant difference in terms of heart rate interfering with the imaging protocol was observed. However, a greater number of arrhythmic heart beats (hb) was observed with the use of LOCM than with IOCM (P< 0.001). There was no difference in subjective image quality between the two CM. The experienced heat sensation was stronger when receiving LOCM than when receiving IOCM (visual analogue scale = 36 mm and 18 mm respectively, P< 0.05).

In Study II the enhancement of liver and aorta was related to different measures of body size and to the use of two different CM (LOCM iomeprol and IOCM iodixanol) in 100 patients undergoing thoraco-abdominal CT. Three parameters had a stronger correlation to the CM enhancement in liver and aorta; Body weight (BW, r= -0.51 and -0.64), body surface area (BSA, r= -0.54 and -0.65) and lean body mass (LBM, r= -0.54 and -0.59), but there was no statistically significant difference between those. The parameters body height (BH), body mass index (BMI) and ideal body weight (IBW) had weaker correlations to CM enhancement of liver and aorta. When adjusting for differences in weight, height, age and sex between the two groups there was a stronger liver enhancement after injection of the IOCM iodixanol than after injection of the LOCM iodixanol (mean difference 6 HU, p < 0.01).

Conclusion: The iso osmolar contrast media iodixanol causes less arrhythmic hb and less heat sensation than the low osmolar contrast media iomeprol, but this does not significantly influence the quality at CCTA. The CM enhancement is affected by body size. There is no statistically significant better parameter than BW to adjust for, why this parameter is recommended for dose adjustments. When performing hepatic imaging the IOCM iodixanol might be preferred to the LOCM iomeprol due to a stronger CM enhancement, but confirming studies are required.

List of scientific papers

I. Heart rate variability and heat sensation at CT coronary angiography: Low-osmolar versus iso-osmolar contrast media. Svensson A, Ripsweden J, Rück A, Aspelin P, Cederlund K, Brismar B. T. Acta Radiol. 2010 Sep; 51(7):722-6.
https://doi.org/10.3109/02841851.2010.488249

II. Hepatic contrast medium enhancement at computed tomography and its correlation with various body size measures. Svensson A, Jallo N, Cederlund K, Aspelin P, Nyman U, Björk J, Brismar B. T. [Submitted]

History

Defence date

2012-06-01

Department

  • Department of Clinical Science, Intervention and Technology

Publisher/Institution

Karolinska Institutet

Main supervisor

Brismar, Torkel B

Publication year

2012

Thesis type

  • Licentiate thesis

ISBN

978-91-7457-733-4

Number of supporting papers

2

Language

  • eng

Original publication date

2012-05-09

Author name in thesis

Svensson, Anders

Original department name

Department of Clinical Science, Intervention and Technology

Place of publication

Stockholm